<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ECG/EKG Archives - Bilaney Consultants</title>
	<atom:link href="https://bilaney.com/category/iworx/research/ecg-ekg/feed/" rel="self" type="application/rss+xml" />
	<link>https://bilaney.com/category/iworx/research/ecg-ekg/</link>
	<description></description>
	<lastBuildDate>Tue, 09 Sep 2025 13:46:57 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.4</generator>

<image>
	<url>https://bilaney.com/wp-content/uploads/2025/02/favicon-100x100.webp</url>
	<title>ECG/EKG Archives - Bilaney Consultants</title>
	<link>https://bilaney.com/category/iworx/research/ecg-ekg/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Zebrafish ECG  system</title>
		<link>https://bilaney.com/product/zebrafish-ecg-system/</link>
		
		<dc:creator><![CDATA[Bilaney Consulting]]></dc:creator>
		<pubDate>Tue, 25 Feb 2025 12:11:47 +0000</pubDate>
				<guid isPermaLink="false">https://neu.bilaney.com/produkt/zebrafish-ecg-system/</guid>

					<description><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/ZS-200-1.jpg" alt=""></p>
<p><!-- wp:paragraph --></p>
<p>The iWorx ZS-200 Zebrafish ECG Recording and Analysis System provides an ideal way to use this cost-effective model for high throughput, rapid screening of&nbsp;compounds.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p>The LS-ECG LabScribe ECG Analysis Module provides an array of analysis options, including T and QT segment shortening and prolongation, which are a key indicator of cardiac function.</p>
<p><!-- /wp:paragraph --></p>
<p>Der Beitrag <a href="https://bilaney.com/product/zebrafish-ecg-system/">Zebrafish ECG  system</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/ZS-200-1.jpg" alt=""></p><!-- wp:paragraph -->
<p>The iWorx ZS-200 Zebrafish ECG Recording and Analysis System provides an ideal way to use this cost-effective model for high throughput, rapid screening of&nbsp;compounds.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>The LS-ECG LabScribe ECG Analysis Module provides an array of analysis options, including T and QT segment shortening and prolongation, which are a key indicator of cardiac function.</p>
<!-- /wp:paragraph --><p>Der Beitrag <a href="https://bilaney.com/product/zebrafish-ecg-system/">Zebrafish ECG  system</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Intracardiac Electrophysiology Rat System,</title>
		<link>https://bilaney.com/product/intracardiac-electrophysiology-rat-system/</link>
		
		<dc:creator><![CDATA[Bilaney Consulting]]></dc:creator>
		<pubDate>Tue, 25 Feb 2025 12:11:46 +0000</pubDate>
				<guid isPermaLink="false">https://neu.bilaney.com/produkt/intracardiac-electrophysiology-rat-system/</guid>

					<description><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/iWire-EPcath-w-RA-5S.jpg" alt=""></p>
<p><!-- wp:paragraph --></p>
<p>iWorx offers turnkey Intracardiac Electrical Potential Recording and Measurement Systems which include data recorders, amplifiers, cables, catheters and software. Each system has been configured to address the subject being studied and acquisition requirements.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">Overview</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:paragraph --></p>
<p>The small animal electrophysiology catheter is designed for intracardiac electrophysiology studies in mice and rats. It is frequently used to investigate cardiac arrhythmias by delivering pacing and recording signals from inside the heart. This tool helps researchers analyze the electrical properties of the atria and ventricles, making it essential for standard electrophysiological research in rodents and similar experimental animals.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p>The platinum needle electrodes can be used to record a surface ECG from the animal as well.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">Product Features</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Monitor intracardiac electrical signals</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Capable of simultaneously collecting ECG signals from multiple locations </li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Can collect signals and deliver stimulation simultaneously </li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Customizable electrode quantity, size and spacing </li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">Standard Sizing</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Mice intracardiac catheter – 1.2F</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Rat intracardiac catheter – 2.4F</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">Applications</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Bundle of His characterization</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>SA node characterization</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>General signal propagation</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Endocardial ECG assessment</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Regional atrial assessment</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Conduction studies</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Qualification of cardiac insult</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">System Includes</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>IX-RA5S data recorder​ The iWorx RA5S data acquisition system with High Voltage Stimulator demonstrates the high resolution, low noise and flexibility required for a variety of research applications</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Octapolar EP Catheter Mouse Intracardiac: 1.3F Electrode spacing 1 mm, Electrode width 1 mm</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Complete Small Animal Heater Controller SA-TCS-6: Heater controller with a 6” x 8” heated bed for mice<br />SA-TCS-8: Heater controller with a 8"x10" heated bed for rats.</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Platinum Needle Electrodes C-ISO-PN3 : 3 subdermal platinum needle electrodes</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Electrophysiology Catheter interface iWire-EPcath</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li> Cables C-BNC-2mmM : BNC to 2mm Male Pin cable<br />C-HVS-2mmM: 2 Safety Connector to 2mm Male Pin cable<br />C-ISO-2mmM: 3x, 2mm Male Pin to Female Safety Pin cable</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>LabScribe ECG analysis software LabScribe Data acquisition and analysis software with the advanced ECG analysis module.</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p>Der Beitrag <a href="https://bilaney.com/product/intracardiac-electrophysiology-rat-system/">Intracardiac Electrophysiology Rat System,</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/iWire-EPcath-w-RA-5S.jpg" alt=""></p><!-- wp:paragraph -->
<p>iWorx offers turnkey Intracardiac Electrical Potential Recording and Measurement Systems which include data recorders, amplifiers, cables, catheters and software. Each system has been configured to address the subject being studied and acquisition requirements.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Overview</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>The small animal electrophysiology catheter is designed for intracardiac electrophysiology studies in mice and rats. It is frequently used to investigate cardiac arrhythmias by delivering pacing and recording signals from inside the heart. This tool helps researchers analyze the electrical properties of the atria and ventricles, making it essential for standard electrophysiological research in rodents and similar experimental animals.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>The platinum needle electrodes can be used to record a surface ECG from the animal as well.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Product Features</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Monitor intracardiac electrical signals</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Capable of simultaneously collecting ECG signals from multiple locations </li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Can collect signals and deliver stimulation simultaneously </li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Customizable electrode quantity, size and spacing </li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Standard Sizing</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Mice intracardiac catheter – 1.2F</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Rat intracardiac catheter – 2.4F</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Applications</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Bundle of His characterization</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>SA node characterization</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>General signal propagation</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Endocardial ECG assessment</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Regional atrial assessment</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Conduction studies</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Qualification of cardiac insult</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading -->
<h2 class="wp-block-heading">System Includes</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>IX-RA5S data recorder​ The iWorx RA5S data acquisition system with High Voltage Stimulator demonstrates the high resolution, low noise and flexibility required for a variety of research applications</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Octapolar EP Catheter Mouse Intracardiac: 1.3F Electrode spacing 1 mm, Electrode width 1 mm</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Complete Small Animal Heater Controller SA-TCS-6: Heater controller with a 6” x 8” heated bed for mice<br>SA-TCS-8: Heater controller with a 8"x10" heated bed for rats.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Platinum Needle Electrodes C-ISO-PN3 : 3 subdermal platinum needle electrodes</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Electrophysiology Catheter interface iWire-EPcath</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li> Cables C-BNC-2mmM : BNC to 2mm Male Pin cable<br>C-HVS-2mmM: 2 Safety Connector to 2mm Male Pin cable<br>C-ISO-2mmM: 3x, 2mm Male Pin to Female Safety Pin cable<br></li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>LabScribe ECG analysis software LabScribe Data acquisition and analysis software with the advanced ECG analysis module.</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list --><p>Der Beitrag <a href="https://bilaney.com/product/intracardiac-electrophysiology-rat-system/">Intracardiac Electrophysiology Rat System,</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Neonatal Mouse ECG System</title>
		<link>https://bilaney.com/product/neonatal-mouse-ecg-system/</link>
		
		<dc:creator><![CDATA[Bilaney Consulting]]></dc:creator>
		<pubDate>Tue, 25 Feb 2025 12:11:46 +0000</pubDate>
				<guid isPermaLink="false">https://neu.bilaney.com/produkt/neonatal-mouse-ecg-system/</guid>

					<description><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/RS-NMECG-1.jpg" alt=""></p>
<p><!-- wp:paragraph --></p>
<p>Features:</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Non-Invasive</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Measure Lead I and Lead II</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Calculate Lead III, aVR, aVL, aVF</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Measure Respiration</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Built-in Heater to maintain the animal body temperature</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Simple, Compact, USB powered</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p>Der Beitrag <a href="https://bilaney.com/product/neonatal-mouse-ecg-system/">Neonatal Mouse ECG System</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/RS-NMECG-1.jpg" alt=""></p><!-- wp:paragraph -->
<p>Features:</p>
<!-- /wp:paragraph -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Non-Invasive</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Measure Lead I and Lead II</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Calculate Lead III, aVR, aVL, aVF</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Measure Respiration</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Built-in Heater to maintain the animal body temperature</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Simple, Compact, USB powered</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list --><p>Der Beitrag <a href="https://bilaney.com/product/neonatal-mouse-ecg-system/">Neonatal Mouse ECG System</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Intracardiac Electrophysiology Mouse System,</title>
		<link>https://bilaney.com/product/intracardiac-electrophysiology-mouse-system/</link>
		
		<dc:creator><![CDATA[Bilaney Consulting]]></dc:creator>
		<pubDate>Tue, 25 Feb 2025 12:11:46 +0000</pubDate>
				<guid isPermaLink="false">https://neu.bilaney.com/produkt/intracardiac-electrophysiology-mouse-system/</guid>

					<description><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/iWire-EPcath-w-RA-5S.jpg" alt=""></p>
<p><!-- wp:paragraph --></p>
<p>iWorx offers turnkey Intracardiac Electrical Potential Recording and Measurement Systems which include data recorders, amplifiers, cables, catheters and software. Each system has been configured to address the subject being studied and acquisition requirements.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">Overview</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:paragraph --></p>
<p>The small animal electrophysiology catheter is designed for intracardiac electrophysiology studies in mice and rats. It is frequently used to investigate cardiac arrhythmias by delivering pacing and recording signals from inside the heart. This tool helps researchers analyze the electrical properties of the atria and ventricles, making it essential for standard electrophysiological research in rodents and similar experimental animals.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p>The platinum needle electrodes can be used to record a surface ECG from the animal as well.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">Product Features</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Monitor intracardiac electrical signals</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Capable of simultaneously collecting ECG signals from multiple locations </li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Can collect signals and deliver stimulation simultaneously </li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Customizable electrode quantity, size and spacing </li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">Standard Sizing</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Mice intracardiac catheter – 1.2F</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Rat intracardiac catheter – 2.4F</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">Applications</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Bundle of His characterization</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>SA node characterization</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>General signal propagation</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Endocardial ECG assessment</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Regional atrial assessment</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Conduction studies</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Qualification of cardiac insult</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">System Includes</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>IX-RA5S data recorder​ The iWorx RA5S data acquisition system with High Voltage Stimulator demonstrates the high resolution, low noise and flexibility required for a variety of research applications</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Octapolar EP Catheter Mouse Intracardiac: 1.3F Electrode spacing 1 mm, Electrode width 1 mm</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Complete Small Animal Heater Controller SA-TCS-6: Heater controller with a 6” x 8” heated bed for mice<br />SA-TCS-8: Heater controller with a 8"x10" heated bed for rats.</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Platinum Needle Electrodes C-ISO-PN3 : 3 subdermal platinum needle electrodes</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Electrophysiology Catheter interface iWire-EPcath</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Cables C-BNC-2mmM : BNC to 2mm Male Pin cable<br />C-HVS-2mmM: 2 Safety Connector to 2mm Male Pin cable<br />C-ISO-2mmM: 3x, 2mm Male Pin to Female Safety Pin cable</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>LabScribe ECG analysis software LabScribe Data acquisition and analysis software with the advanced ECG analysis module.</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p>Der Beitrag <a href="https://bilaney.com/product/intracardiac-electrophysiology-mouse-system/">Intracardiac Electrophysiology Mouse System,</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/iWire-EPcath-w-RA-5S.jpg" alt=""></p><!-- wp:paragraph -->
<p>iWorx offers turnkey Intracardiac Electrical Potential Recording and Measurement Systems which include data recorders, amplifiers, cables, catheters and software. Each system has been configured to address the subject being studied and acquisition requirements.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Overview</h2>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>The small animal electrophysiology catheter is designed for intracardiac electrophysiology studies in mice and rats. It is frequently used to investigate cardiac arrhythmias by delivering pacing and recording signals from inside the heart. This tool helps researchers analyze the electrical properties of the atria and ventricles, making it essential for standard electrophysiological research in rodents and similar experimental animals.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>The platinum needle electrodes can be used to record a surface ECG from the animal as well.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Product Features</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Monitor intracardiac electrical signals</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Capable of simultaneously collecting ECG signals from multiple locations </li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Can collect signals and deliver stimulation simultaneously </li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Customizable electrode quantity, size and spacing </li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Standard Sizing</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Mice intracardiac catheter – 1.2F</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Rat intracardiac catheter – 2.4F</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Applications</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Bundle of His characterization</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>SA node characterization</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>General signal propagation</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Endocardial ECG assessment</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Regional atrial assessment</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Conduction studies</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Qualification of cardiac insult</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading -->
<h2 class="wp-block-heading">System Includes</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>IX-RA5S data recorder​ The iWorx RA5S data acquisition system with High Voltage Stimulator demonstrates the high resolution, low noise and flexibility required for a variety of research applications</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Octapolar EP Catheter Mouse Intracardiac: 1.3F Electrode spacing 1 mm, Electrode width 1 mm</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Complete Small Animal Heater Controller SA-TCS-6: Heater controller with a 6” x 8” heated bed for mice<br>SA-TCS-8: Heater controller with a 8"x10" heated bed for rats.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Platinum Needle Electrodes C-ISO-PN3 : 3 subdermal platinum needle electrodes</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Electrophysiology Catheter interface iWire-EPcath</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Cables C-BNC-2mmM : BNC to 2mm Male Pin cable<br>C-HVS-2mmM: 2 Safety Connector to 2mm Male Pin cable<br>C-ISO-2mmM: 3x, 2mm Male Pin to Female Safety Pin cable<br></li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>LabScribe ECG analysis software LabScribe Data acquisition and analysis software with the advanced ECG analysis module.</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list --><p>Der Beitrag <a href="https://bilaney.com/product/intracardiac-electrophysiology-mouse-system/">Intracardiac Electrophysiology Mouse System,</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RS-ECG12-LA: Large Animal 12-Lead ECG System</title>
		<link>https://bilaney.com/product/rs-ecg12-la-large-animal-12-lead-ecg-system/</link>
		
		<dc:creator><![CDATA[Bilaney Consulting]]></dc:creator>
		<pubDate>Tue, 25 Feb 2025 12:11:45 +0000</pubDate>
				<guid isPermaLink="false">https://neu.bilaney.com/produkt/12-lead-ecg-recorder-with-labscribe-software-and-ecg-analysis-module/</guid>

					<description><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/IX-ECG12_SL9.jpg" alt=""></p>
<p><!-- wp:paragraph --></p>
<p>The iWorx 12 lead ECG recorder enables accurate and reliable ECG measurement and analysis of humans or animals. Measuring all 12 ECG leads simultaneously, this compact and lightweight PC-based ECG recorder enables highly detailed analysis of the anterior, lateral and inferior regions of the heart.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p>The RS-ECG12 system is optimized for measuring large animal ECG.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p>The iWorx 12 lead ECG recorder enables accurate and reliable ECG analysis of resting animals. Measuring all 12 ECG leads simultaneously, this compact and lightweight PC-based ECG recorder enables highly detailed analysis of the anterior, lateral and inferior regions of the heart. The IX-ECG12 connects to and is powered by a USB port on any Windows or Macintosh computer. Data is recorded and analyzed with iWorx advanced LabScribe ECG Software Module.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">System Includes</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>IX-ECG12 12 Lead ECG Recorder Record all 12 ECG leads Lead I, Lead II, Lead III, aVr, aVl, aVf, V1, V2,V3, V4, V5, V6 simultaneously from a single subject.</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>LabScribe Data Acquisition and Analysis Software LabScribe Data acquisition and analysis software</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>LabScribe ECG Analysis Software LabScribe Data acquisition and analysis software with the advanced ECG analysis module.</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Snap Lead Electrodes C-ISO-SL10: set of 10 snap lead electrodes</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>ECG Electrodes Disposable ECG Ag-AGCl electrodes (package of 50)</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading {"level":3} --></p>
<h3 class="wp-block-heading">Templates for Different Species</h3>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Human</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Small Dog</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Large Dog</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Pig</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Rabbit</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Guinea Pig</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Mouse</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Rat</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Zebrafish </li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading {"level":3} --></p>
<h3 class="wp-block-heading">Measurements</h3>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Measure various intervals such as: QRS, QT, QTc, QR, ST Pb-R, P-R, Pe-R, Qb-R, Q-R, S-R, Se-R, Tb-R, T-R, Te-R</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Amplitudes such as: P , Q, R, S , T, ST elevation, QR Amp</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading {"level":3} --></p>
<h3 class="wp-block-heading">Filtering and Averaging</h3>
<p><!-- /wp:heading --></p>
<p><!-- wp:paragraph --></p>
<p>Use FIR and Notch filters to filer out the noise from the ECG signal before processing.&nbsp;</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p>Multiple cycles can also be average further reducing the noise. Average by specified number of beats, or specified time interval.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:heading {"level":3} --></p>
<h3 class="wp-block-heading">Graphical Display of Detected Points</h3>
<p><!-- /wp:heading --></p>
<p><!-- wp:paragraph --></p>
<p>The following locations are displayed on the ECG waveform:</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Beginning, peak and end of P</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Beginning of Q</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>peak of R wave</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>End of S</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Beginning, peak and end of T wave</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading {"level":3} --></p>
<h3 class="wp-block-heading">Outliers and Artifacts</h3>
<p><!-- /wp:heading --></p>
<p><!-- wp:paragraph --></p>
<p>Outlier removal based on abnormal R-R intervals, heart rate, noise,&nbsp; activity, P amplitude, and T amplitude.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p>Manually mark outliers if needed.  A list of outliers is displayed.</p>
<p><!-- /wp:paragraph --></p>
<p>Der Beitrag <a href="https://bilaney.com/product/rs-ecg12-la-large-animal-12-lead-ecg-system/">RS-ECG12-LA: Large Animal 12-Lead ECG System</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/IX-ECG12_SL9.jpg" alt=""></p><!-- wp:paragraph -->
<p>The iWorx 12 lead ECG recorder enables accurate and reliable ECG measurement and analysis of humans or animals. Measuring all 12 ECG leads simultaneously, this compact and lightweight PC-based ECG recorder enables highly detailed analysis of the anterior, lateral and inferior regions of the heart.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>The RS-ECG12 system is optimized for measuring large animal ECG.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>The iWorx 12 lead ECG recorder enables accurate and reliable ECG analysis of resting animals. Measuring all 12 ECG leads simultaneously, this compact and lightweight PC-based ECG recorder enables highly detailed analysis of the anterior, lateral and inferior regions of the heart. The IX-ECG12 connects to and is powered by a USB port on any Windows or Macintosh computer. Data is recorded and analyzed with iWorx advanced LabScribe ECG Software Module.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">System Includes</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>IX-ECG12 12 Lead ECG Recorder Record all 12 ECG leads Lead I, Lead II, Lead III, aVr, aVl, aVf, V1, V2,V3, V4, V5, V6 simultaneously from a single subject.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>LabScribe Data Acquisition and Analysis Software LabScribe Data acquisition and analysis software</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>LabScribe ECG Analysis Software LabScribe Data acquisition and analysis software with the advanced ECG analysis module.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Snap Lead Electrodes C-ISO-SL10: set of 10 snap lead electrodes</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>ECG Electrodes Disposable ECG Ag-AGCl electrodes (package of 50)</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading {"level":3} -->
<h3 class="wp-block-heading">Templates for Different Species</h3>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Human</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Small Dog</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Large Dog</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Pig</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Rabbit</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Guinea Pig</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Mouse</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Rat</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Zebrafish </li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading {"level":3} -->
<h3 class="wp-block-heading">Measurements</h3>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Measure various intervals such as: QRS, QT, QTc, QR, ST Pb-R, P-R, Pe-R, Qb-R, Q-R, S-R, Se-R, Tb-R, T-R, Te-R</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Amplitudes such as: P , Q, R, S , T, ST elevation, QR Amp</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading {"level":3} -->
<h3 class="wp-block-heading">Filtering and Averaging</h3>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Use FIR and Notch filters to filer out the noise from the ECG signal before processing.&nbsp;</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>Multiple cycles can also be average further reducing the noise. Average by specified number of beats, or specified time interval.</p>
<!-- /wp:paragraph -->

<!-- wp:heading {"level":3} -->
<h3 class="wp-block-heading">Graphical Display of Detected Points</h3>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>The following locations are displayed on the ECG waveform:</p>
<!-- /wp:paragraph -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Beginning, peak and end of P</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Beginning of Q</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>peak of R wave</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>End of S</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Beginning, peak and end of T wave</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading {"level":3} -->
<h3 class="wp-block-heading">Outliers and Artifacts</h3>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Outlier removal based on abnormal R-R intervals, heart rate, noise,&nbsp; activity, P amplitude, and T amplitude.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>Manually mark outliers if needed.  A list of outliers is displayed.</p>
<!-- /wp:paragraph --><p>Der Beitrag <a href="https://bilaney.com/product/rs-ecg12-la-large-animal-12-lead-ecg-system/">RS-ECG12-LA: Large Animal 12-Lead ECG System</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RS-ECG6-LA: Large Animal 6-Lead ECG System</title>
		<link>https://bilaney.com/product/rs-ecg6-la-large-animal-6-lead-ecg-system/</link>
		
		<dc:creator><![CDATA[Bilaney Consulting]]></dc:creator>
		<pubDate>Tue, 25 Feb 2025 12:11:45 +0000</pubDate>
				<guid isPermaLink="false">https://neu.bilaney.com/produkt/6-lead-ecg-recorder-with-labscribe-software-and-ecg-analysis-module/</guid>

					<description><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/IX-ECG6_SL3.jpg" alt=""></p>
<p><!-- wp:paragraph --></p>
<p>The iWorx 6 lead ECG recorder enables accurate and reliable ECG measurement and analysis of humans or animals. Measuring 6 ECG leads LeadI, Lead II, Lead III, aVr, aVl and aVf simultaneously, this compact and lightweight PC-based ECG recorder enables highly detailed analysis of the anterior, lateral and inferior regions of the heart.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p>The RS-ECG6 system is optimized for measuring large animal ECG.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p>The IX-ECG6 connects to and is powered by a USB port on any Windows or Macintosh computer. Data is recorded and analyzed with iWorx advanced LabScribe ECG Software Module.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">System Includes</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>IX-ECG6 6 Lead ECG Recorder Record 6 ECG leads Lead I, Lead II, Lead III, aVr, aVl, aVf, simultaneously from a single subject.</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>LabScribe Data Acquisition and Analysis Software LabScribe Data acquisition and analysis software</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>LabScribe ECG Analysis Software LabScribe Data acquisition and analysis software with the advanced ECG analysis module.</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Snap Lead Electrodes C-ISO-SL4: set of 4 snap lead electrodes</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading {"level":3} --></p>
<h3 class="wp-block-heading">Templates for Different Species</h3>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Human</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Small Dog</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Large Dog</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Pig</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Rabbit</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Guinea Pig</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Mouse</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Rat</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Zebrafish </li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading {"level":3} --></p>
<h3 class="wp-block-heading">Measurements</h3>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Measure various intervals such as: QRS, QT, QTc, QR, ST Pb-R, P-R, Pe-R, Qb-R, Q-R, S-R, Se-R, Tb-R, T-R, Te-R</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Amplitudes such as: P , Q, R, S , T, ST elevation, QR Amp</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading {"level":3} --></p>
<h3 class="wp-block-heading">Filtering and Averaging</h3>
<p><!-- /wp:heading --></p>
<p><!-- wp:paragraph --></p>
<p>Use FIR and Notch filters to filer out the noise from the ECG signal before processing.&nbsp;</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p>Multiple cycles can also be average further reducing the noise. Average by specified number of beats, or specified time interval.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:heading {"level":3} --></p>
<h3 class="wp-block-heading">Graphical Display of Detected Points</h3>
<p><!-- /wp:heading --></p>
<p><!-- wp:paragraph --></p>
<p>The following locations are displayed on the ECG waveform:</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>Beginning, peak and end of P</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Beginning of Q</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>peak of R wave</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>End of S</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Beginning, peak and end of T wave</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading {"level":3} --></p>
<h3 class="wp-block-heading">Outliers and Artifacts</h3>
<p><!-- /wp:heading --></p>
<p><!-- wp:paragraph --></p>
<p>Outlier removal based on abnormal R-R intervals, heart rate, noise,&nbsp; activity, P amplitude, and T amplitude.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p>Manually mark outliers if needed.  A list of outliers is displayed.</p>
<p><!-- /wp:paragraph --></p>
<p>Der Beitrag <a href="https://bilaney.com/product/rs-ecg6-la-large-animal-6-lead-ecg-system/">RS-ECG6-LA: Large Animal 6-Lead ECG System</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/IX-ECG6_SL3.jpg" alt=""></p><!-- wp:paragraph -->
<p>The iWorx 6 lead ECG recorder enables accurate and reliable ECG measurement and analysis of humans or animals. Measuring 6 ECG leads LeadI, Lead II, Lead III, aVr, aVl and aVf simultaneously, this compact and lightweight PC-based ECG recorder enables highly detailed analysis of the anterior, lateral and inferior regions of the heart.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>The RS-ECG6 system is optimized for measuring large animal ECG.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>The IX-ECG6 connects to and is powered by a USB port on any Windows or Macintosh computer. Data is recorded and analyzed with iWorx advanced LabScribe ECG Software Module.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">System Includes</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>IX-ECG6 6 Lead ECG Recorder Record 6 ECG leads Lead I, Lead II, Lead III, aVr, aVl, aVf, simultaneously from a single subject.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>LabScribe Data Acquisition and Analysis Software LabScribe Data acquisition and analysis software</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>LabScribe ECG Analysis Software LabScribe Data acquisition and analysis software with the advanced ECG analysis module.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Snap Lead Electrodes C-ISO-SL4: set of 4 snap lead electrodes</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading {"level":3} -->
<h3 class="wp-block-heading">Templates for Different Species</h3>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Human</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Small Dog</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Large Dog</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Pig</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Rabbit</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Guinea Pig</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Mouse</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Rat</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Zebrafish </li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading {"level":3} -->
<h3 class="wp-block-heading">Measurements</h3>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Measure various intervals such as: QRS, QT, QTc, QR, ST Pb-R, P-R, Pe-R, Qb-R, Q-R, S-R, Se-R, Tb-R, T-R, Te-R</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Amplitudes such as: P , Q, R, S , T, ST elevation, QR Amp</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading {"level":3} -->
<h3 class="wp-block-heading">Filtering and Averaging</h3>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Use FIR and Notch filters to filer out the noise from the ECG signal before processing.&nbsp;</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>Multiple cycles can also be average further reducing the noise. Average by specified number of beats, or specified time interval.</p>
<!-- /wp:paragraph -->

<!-- wp:heading {"level":3} -->
<h3 class="wp-block-heading">Graphical Display of Detected Points</h3>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>The following locations are displayed on the ECG waveform:</p>
<!-- /wp:paragraph -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>Beginning, peak and end of P</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Beginning of Q</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>peak of R wave</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>End of S</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Beginning, peak and end of T wave</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading {"level":3} -->
<h3 class="wp-block-heading">Outliers and Artifacts</h3>
<!-- /wp:heading -->

<!-- wp:paragraph -->
<p>Outlier removal based on abnormal R-R intervals, heart rate, noise,&nbsp; activity, P amplitude, and T amplitude.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>Manually mark outliers if needed.  A list of outliers is displayed.</p>
<!-- /wp:paragraph --><p>Der Beitrag <a href="https://bilaney.com/product/rs-ecg6-la-large-animal-6-lead-ecg-system/">RS-ECG6-LA: Large Animal 6-Lead ECG System</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ROAM Wireless ECG &#038; Respiration without Accelerometer</title>
		<link>https://bilaney.com/product/roam-wireless-ecg-respiration-without-accelerometer/</link>
		
		<dc:creator><![CDATA[Bilaney Consulting]]></dc:creator>
		<pubDate>Tue, 25 Feb 2025 12:11:38 +0000</pubDate>
				<guid isPermaLink="false">https://neu.bilaney.com/produkt/wireless-1-channel-ecg-with-respiration-system-with-labscribe-software/</guid>

					<description><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/IXR-B2A-1.jpg" alt=""></p>
<p><!-- wp:paragraph --></p>
<p>The iWorx ROAM Wireless ECG is a wearable system designed to provide long-term recording and unrestricted movement. The recording device easily attaches to the subject with standard electrodes. The protective case doubles as a charging station. The system works with both Windows and MacOS via standard USB interface. Data can be quickly analyzed with the included LabScribe analysis software or exported directly for other processing. The ROAM Wireless ECG allows for hours of continuous recording with an untethered reach of 20 feet.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">Features</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>8+ Hours of Continuous Recording</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Plug and Play Technology</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>No Syncing Required</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>PC and Mac compatible</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>USB-Powered</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>EMG, Respiration and Accelerometer measurements available</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Includes LabScribe Software for Data collection and Analysis</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">System Includes</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>ROAM wireless EMG/ECG Recorder</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>ROAM wireless USB receiver</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>LabScribe Recording and Analysis Software</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Retractable USB cable</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Hard-Shell case for Charging and Storage</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:paragraph --></p>
<p><!-- /wp:paragraph --></p>
<p>Der Beitrag <a href="https://bilaney.com/product/roam-wireless-ecg-respiration-without-accelerometer/">ROAM Wireless ECG &#038; Respiration without Accelerometer</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/IXR-B2A-1.jpg" alt=""></p><!-- wp:paragraph -->
<p>The iWorx ROAM Wireless ECG is a wearable system designed to provide long-term recording and unrestricted movement. The recording device easily attaches to the subject with standard electrodes. The protective case doubles as a charging station. The system works with both Windows and MacOS via standard USB interface. Data can be quickly analyzed with the included LabScribe analysis software or exported directly for other processing. The ROAM Wireless ECG allows for hours of continuous recording with an untethered reach of 20 feet.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Features</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>8+ Hours of Continuous Recording</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Plug and Play Technology</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>No Syncing Required</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>PC and Mac compatible</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>USB-Powered</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>EMG, Respiration and Accelerometer measurements available</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Includes LabScribe Software for Data collection and Analysis</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading -->
<h2 class="wp-block-heading">System Includes</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>ROAM wireless EMG/ECG Recorder</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>ROAM wireless USB receiver</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>LabScribe Recording and Analysis Software</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Retractable USB cable</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Hard-Shell case for Charging and Storage</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:paragraph -->
<p></p>
<!-- /wp:paragraph --><p>Der Beitrag <a href="https://bilaney.com/product/roam-wireless-ecg-respiration-without-accelerometer/">ROAM Wireless ECG &#038; Respiration without Accelerometer</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ROAM Wireless ECG &#038; Respiration with Accelerometer</title>
		<link>https://bilaney.com/product/roam-wireless-ecg-respiration-with-accelerometer/</link>
		
		<dc:creator><![CDATA[Bilaney Consulting]]></dc:creator>
		<pubDate>Tue, 25 Feb 2025 12:11:38 +0000</pubDate>
				<guid isPermaLink="false">https://neu.bilaney.com/produkt/wireless-ecg-respiration-and-accelerometer-system-with-labscribe-software/</guid>

					<description><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/IXR-B2A-1.jpg" alt=""></p>
<p><!-- wp:paragraph --></p>
<p>The iWorx ROAM Wireless ECG is a wearable system designed to provide long-term recording and unrestricted movement. The recording device easily attaches to the subject with standard electrodes. The protective case doubles as a charging station. The system works with both Windows and MacOS via standard USB interface. Data can be quickly analyzed with the included LabScribe analysis software or exported directly for other processing. The ROAM Wireless ECG allows for hours of continuous recording with an untethered reach of 20 feet.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">Features</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>8+ Hours of Continuous Recording</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Plug and Play Technology</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>No Syncing Required</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>PC and Mac compatible</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>USB-Powered</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>EMG, Respiration and Accelerometer measurements available</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Includes LabScribe Software for Data collection and Analysis</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">System Includes</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>ROAM wireless EMG/ECG Recorder</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>ROAM wireless USB receiver</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>LabScribe Recording and Analysis Software</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Retractable USB cable</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Hard-Shell case for Charging and Storage</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p>Der Beitrag <a href="https://bilaney.com/product/roam-wireless-ecg-respiration-with-accelerometer/">ROAM Wireless ECG &#038; Respiration with Accelerometer</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/IXR-B2A-1.jpg" alt=""></p><!-- wp:paragraph -->
<p>The iWorx ROAM Wireless ECG is a wearable system designed to provide long-term recording and unrestricted movement. The recording device easily attaches to the subject with standard electrodes. The protective case doubles as a charging station. The system works with both Windows and MacOS via standard USB interface. Data can be quickly analyzed with the included LabScribe analysis software or exported directly for other processing. The ROAM Wireless ECG allows for hours of continuous recording with an untethered reach of 20 feet.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">Features</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>8+ Hours of Continuous Recording</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Plug and Play Technology</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>No Syncing Required</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>PC and Mac compatible</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>USB-Powered</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>EMG, Respiration and Accelerometer measurements available</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Includes LabScribe Software for Data collection and Analysis</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list -->

<!-- wp:heading -->
<h2 class="wp-block-heading">System Includes</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>ROAM wireless EMG/ECG Recorder</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>ROAM wireless USB receiver</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>LabScribe Recording and Analysis Software</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Retractable USB cable</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Hard-Shell case for Charging and Storage</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list --><p>Der Beitrag <a href="https://bilaney.com/product/roam-wireless-ecg-respiration-with-accelerometer/">ROAM Wireless ECG &#038; Respiration with Accelerometer</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>RS-ECG-SA: Small Animal ECG System</title>
		<link>https://bilaney.com/product/rs-ecg-sa-small-animal-ecg-system/</link>
		
		<dc:creator><![CDATA[Bilaney Consulting]]></dc:creator>
		<pubDate>Tue, 25 Feb 2025 12:11:36 +0000</pubDate>
				<guid isPermaLink="false">https://neu.bilaney.com/produkt/small-animal-ecg-system-includes-ix-ecg-4-platinum-needle-electrodes-ra-la-rl-ll-labscribe-ecg-analysis-module-measure-lead-i-lead-ii-lead-iii-avr-avl-avf/</guid>

					<description><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/IX-ECG6_PN4.jpg" alt=""></p>
<p><!-- wp:paragraph --></p>
<p>The RS-ECG-SA system is optimized for accurate and reliable ECG measurement and analysis of mouse, rat and other small animals.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p>The RS-ECG-SA system is optimized for measuring mouse, rat and other small animal ECG.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:paragraph --></p>
<p>The iWorx 6 lead ECG recorder enables accurate and reliable ECG analysis of resting and exercising humans or animals. Measuring 6 ECG leads simultaneously, this compact and lightweight ECG recorder connects to and is powered by a USB port on any Windows or Macintosh computer. Data is recorded and analyzed with iWorx advanced LabScribe ECG Software Module.</p>
<p><!-- /wp:paragraph --></p>
<p><!-- wp:heading --></p>
<h2 class="wp-block-heading">System Includes</h2>
<p><!-- /wp:heading --></p>
<p><!-- wp:list --></p>
<ul class="wp-block-list"><!-- wp:list-item --></p>
<li>IX-ECG6 6 Lead ECG Recorder Record 6 ECG leads Lead I, Lead II, Lead III, aVr, aVl, and aVf, simultaneously from a single subject.</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>LabScribe Data Acquisition and Analysis Software LabScribe Data acquisition and analysis software</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>LabScribe ECG Analysis Software LabScribe Data acquisition and analysis software with the advanced ECG analysis module.</li>
<p><!-- /wp:list-item --></p>
<p><!-- wp:list-item --></p>
<li>Platinum Needle Electrodes C-ISO-PN4: set of 4 platinum needle electrodes</li>
<p><!-- /wp:list-item --></ul>
<p><!-- /wp:list --></p>
<p>Der Beitrag <a href="https://bilaney.com/product/rs-ecg-sa-small-animal-ecg-system/">RS-ECG-SA: Small Animal ECG System</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><img src="https://bilaney.com/wp-content/uploads/2025/02/IX-ECG6_PN4.jpg" alt=""></p><!-- wp:paragraph -->
<p>The RS-ECG-SA system is optimized for accurate and reliable ECG measurement and analysis of mouse, rat and other small animals.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>The RS-ECG-SA system is optimized for measuring mouse, rat and other small animal ECG.</p>
<!-- /wp:paragraph -->

<!-- wp:paragraph -->
<p>The iWorx 6 lead ECG recorder enables accurate and reliable ECG analysis of resting and exercising humans or animals. Measuring 6 ECG leads simultaneously, this compact and lightweight ECG recorder connects to and is powered by a USB port on any Windows or Macintosh computer. Data is recorded and analyzed with iWorx advanced LabScribe ECG Software Module.</p>
<!-- /wp:paragraph -->

<!-- wp:heading -->
<h2 class="wp-block-heading">System Includes</h2>
<!-- /wp:heading -->

<!-- wp:list -->
<ul class="wp-block-list"><!-- wp:list-item -->
<li>IX-ECG6 6 Lead ECG Recorder Record 6 ECG leads Lead I, Lead II, Lead III, aVr, aVl, and aVf, simultaneously from a single subject.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>LabScribe Data Acquisition and Analysis Software LabScribe Data acquisition and analysis software</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>LabScribe ECG Analysis Software LabScribe Data acquisition and analysis software with the advanced ECG analysis module.</li>
<!-- /wp:list-item -->

<!-- wp:list-item -->
<li>Platinum Needle Electrodes C-ISO-PN4: set of 4 platinum needle electrodes</li>
<!-- /wp:list-item --></ul>
<!-- /wp:list --><p>Der Beitrag <a href="https://bilaney.com/product/rs-ecg-sa-small-animal-ecg-system/">RS-ECG-SA: Small Animal ECG System</a> erschien zuerst auf <a href="https://bilaney.com">Bilaney Consultants</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
